beautypg.com

5 connection list entry, 6 power states, 5 connection list entry 6.8.6 power states – Cirrus Logic CS4207 User Manual

Page 80: Cs4207

background image

80

DS880F4

CS4207

6.8.5

Connection List Entry

Get Parameter Command Format:

Response Format:

6.8.6

Power States

Get Parameter Command Format:

Set Parameter Command Format:

Response Format:

Bits [31:28]

Bits [27:20]

Bits [19:8]

Bits [7:0]

CAd = X

Node ID = 09h

Verb ID = F02h

Payload = N = xxh

Bits

Type

Default

Description

31:24

Read Only

00h

Connection List Entry (N+3):
Returns 00h for N=00h-03h or N>03h.

23:16

Read Only

00h

Connection List Entry (N+2):
Returns 00h for N=00h-03h or N>03h.

15:8

Read Only

00h

Connection List Entry (N+1):
Returns 00h for N=00h-03h or N>03h.

7:0

Read Only

02h

Connection List Entry (N):
Returns 02h (DAC1) for N=00h-03h.
Returns 00h for N>03h.

Bits [31:28]

Bits [27:20]

Bits [19:8]

Bits [7:0]

CAd = X

Node ID = 09h

Verb ID = F05h

Payload = 00h

Bits [31:28]

Bits [27:20]

Bits [19:8]

Bits [7:0]

CAd = X

Node ID = 09h

Verb ID = 705h

Payload = xxh

Bits

Type

Default

Description

31:11

Read Only

00000h

Reserved

10

Read Only

1b

Power State Settings Reset (PS-SettingsRe-

set): This bit is set to ‘1’b when, during any type
of reset or low power state transition, the settings
within this widget that were changed from the
defaults, either by software or hardware, have
been reset back to their default state. When
these settings have not been reset, this is
reported as ‘0’b. This bit is always a ‘1’b follow-
ing a POR condition. For more information, see

“Power State Settings Reset (PS-SettingsRe-
set)” on p 28

9

Read Only

0b

Reserved

8

Read Only

0b

Power State Error (PS-Error): This bit is not
supported and will always return ‘0’b when read.

7:4

Read Only

0011b

Power State Actual (PS-Act): This field indi-
cates the actual power state of the referenced
node. The default state is D3.