68
DS880F4
CS4207
14
Read/Write
0b
Sample Base Rate (BASE):
0 = 48 kHz
1 = 44.1 kHz
13:11
Read/Write
000b
Sample Base Rate Multiple (MULT):
000 = 48 kHz/44.1 kHz or less
001 = x2 (96 kHz, 88.2 kHz, 32 kHz)
010 = x3 (144 kHz)
011 = x4 (192 kHz, 176.4 kHz)
100-111 =
Reserved
10:8
Read/Write
000b
Sample Base Rate Divisor (DIV):
000 = Divide by 1 (48 kHz, 44.1 kHz)
001 = Divide by 2 (24 kHz, 22.05 kHz)
010 = Divide by 3 (16 kHz, 32 kHz)
011 = Divide by 4 (11.025 kHz)
100 = Divide by 5 (9.6 kHz)
101 = Divide by 6 (8 kHz)
110 = Divide by 7
111 = Divide by 8 (6 kHz)
7
Read Only
0b
Reserved
6:4
Read/Write
000b
Bits per Sample (BITS): Number of bits in each
sample:
000 = 8 bits. The data will be packed in memory
in 8-bit containers on 16-bit boundaries.
001 = 16 bits. The data will be packed in memory
in 16-bit containers on 16-bit boundaries.
010 = 20 bits. The data will be packed in memory
in 32-bit containers on 32-bit boundaries.
011 = 24 bits. The data will be packed in memory
in 32-bit containers on 32-bit boundaries.
100 = 32 bits. The data will be packed in memory
in 32-bit containers on 32-bit boundaries.
101-111 =
Reserved
3:0
Read/Write
0000b
Number of Channels (CHAN): Number of chan-
nels in each frame of the stream:
0000 = 1
0001 = 2
…
1111 = 16
Bits
Type
Default
Description