4 s/pdif transmitter 1 connection list entry, 5 s/pdif transmitter 2 connection list entry, Cs4207 – Cirrus Logic CS4207 User Manual
Page 122

122
DS880F4
CS4207
6.14.4
S/PDIF Transmitter 1 Connection List Entry
Get Parameter Command Format:
Response Format:
6.14.5
S/PDIF Transmitter 2 Connection List Entry
Get Parameter Command Format:
Response Format:
Bits [31:28]
Bits [27:20]
Bits [19:8]
Bits [7:0]
CAd = X
Node ID = 10h
Verb ID = F02h
Payload = N = xxh
Bits
Type
Default
Description
31:24
Read Only
00h
Connection List Entry (N+3):
Returns 00h for N=00h-03h or N>03h.
23:16
Read Only
00h
Connection List Entry (N+2):
Returns 00h for N=00h-03h or N>03h.
15:8
Read Only
00h
Connection List Entry (N+1):
Returns 00h for N=00h-03h or N>03h.
7:0
Read Only
08h
Connection List Entry (N):
Returns 08h (S/PDIF Out 1) for N=00h-03h.
Returns 00h for N>03h.
Bits [31:28]
Bits [27:20]
Bits [19:8]
Bits [7:0]
CAd = X
Node ID = 15h
Verb ID = F02h
Payload = N = xxh
Bits
Type
Default
Description
31:24
Read Only
00h
Connection List Entry (N+3):
Returns 00h for N=00h-03h or N>03h.
23:16
Read Only
00h
Connection List Entry (N+2):
Returns 00h for N=00h-03h or N>03h.
15:8
Read Only
00h
Connection List Entry (N+1):
Returns 00h for N=00h-03h or N>03h.
7:0
Read Only
14h
Connection List Entry (N):
Returns 14h (S/PDIF Out 2) for N=00h-03h.
Returns 00h for N>03h.