7 converter stream, channel, 8 converter format, 7 converter stream, channel 6.4.8 converter format – Cirrus Logic CS4207 User Manual
Page 49: Cs4207

DS880F4
49
CS4207
6.4.7
Converter Stream, Channel
Get Parameter Command Format:
Set Parameter Command Format:
Response Format:
6.4.8
Converter Format
Get Parameter Command Format:
Set Parameter Command Format:
Bits [31:28]
Bits [27:20]
Bits [19:8]
Bits [7:0]
CAd = X
DAC1 Node ID=02h
DAC2 Node ID=03h
DAC3 Node ID=04h
Verb ID = F06h
Payload = 00h
Bits [31:28]
Bits [27:20]
Bits [19:8]
Bits [7:0]
CAd = X
DAC1 Node ID=02h
DAC2 Node ID=03h
DAC3 Node ID=04h
Verb ID = 706h
Payload = xxh
Bits
Type
Default
Description
31:8
Read Only
000000h
Reserved
7:4
Read/Write
0h
Stream Number (SN): This field is written by
software to indicate the stream number used by
the Output Converter. “0h” is stream 0, “1h” is
stream 1, etc.
By convention, stream 0 is reserved and unused
so that converter whose stream number has
been reset to “0h” does not unintentionally
decode data not intended for them.
3:0
Read/Write
0h
Lowest Channel Number (LCN): This field is
written by software to indicate the lowest channel
used by the Output Converter. The stereo con-
verter will use this LCN value plus 1 for its left
and right channel.
Bits [31:28]
Bits [27:20]
Bits [19:16]
Bits [15:0]
CAd = X
DAC1 Node ID=02h
DAC2 Node ID=03h
DAC3 Node ID=04h
Verb ID = Ah
Payload = 0000h
Bits [31:28]
Bits [27:20]
Bits [19:16]
Bits [15:0]
CAd = X
DAC1 Node ID=02h
DAC2 Node ID=03h
DAC3 Node ID=04h
Verb ID = 2h
Payload = xxxxh