Fitting the electric components – Festo Линейный привод с датчиком перемещения DGPIL User Manual
Page 28

DGPI(L)−...−AI F
Festo DGPI(L)−...−AIF 0409a English
28
Fitting the electric components
S
Wire the earth connection with earth potential.
ć Cable cross sectional area at least 1.5 mm
2
.
ć Cable length max. 10 m.
S Insert the screw with cutting thread (included in delivery) into the hole for
the earth connection
9 (see Fig. 1).
This will guarantee electrical contact despite the anodized coating.
S
Wire the measuring system connection together with the control system.
Only the original cable may be used for this purpose (Pin assignment see
Fig. 16).
Measuring system connection
PIN
Assignment
1
CAN−Low
4
5
2
CAN−High
3
4
5
6
3
n.c.
1
2
3
6
4
n.c.
5
+24 V DC
6
0 V
n.c. = not connected
Fig. 16
Note that the permanent magnet fitted in the piston is only suitable for operating
the integrated measuring system.
Proximity switches with magnetic actuation cannot be used.