beautypg.com

Fitting the electric components – Festo Линейный привод с датчиком перемещения DGPIL User Manual

Page 28

background image

DGPI(L)−...−AI F

Festo DGPI(L)−...−AIF 0409a English

28

Fitting the electric components

S

Wire the earth connection with earth potential.

ć Cable cross sectional area at least 1.5 mm

2

.

ć Cable length max. 10 m.

S Insert the screw with cutting thread (included in delivery) into the hole for

the earth connection

9 (see Fig. 1).

This will guarantee electrical contact despite the anodized coating.

S

Wire the measuring system connection together with the control system.

Only the original cable may be used for this purpose (Pin assignment see
Fig. 16).

Measuring system connection

PIN

Assignment

1

CAN−Low

4

5

2

CAN−High

3

4

5

6

3

n.c.

1

2

3

6

4

n.c.

5

+24 V DC

6

0 V

n.c. = not connected

Fig. 16

Note that the permanent magnet fitted in the piston is only suitable for operating
the integrated measuring system.
Proximity switches with magnetic actuation cannot be used.