elektraLite CP100xt Manual Part One User Manual
Page 62

62
type
string the name of the fixture type, up to fourteen characters.
For example: Miniscan
stage
switch
yes
if the fixture supports stage focus. If this isn’t specified, the default is
ye
s,
although if the fixture type doesn’t have both pan and tilt features, it has no effect. If a fixture type
has
pan
and tilt features and this is on, the attribute list includes the Stage Focus coordinates
P0
0,
P0
1,
P1
0,
P1
1,
T0
0,
T0
1,
T10
and
T1
1.
stage
equivalent to
stage of
f.
scale
number the ratio between the scaling of the coarse pan or tilt feature to the fine, for high-
resolution steer-able fixtures. The range is 2 to 256, and the default is 256. This is ignored if the
fixture doesn’t have high-resolution pan and tilt features. Next, the features are listed, in order of
physical channel. Each feature is represented by any combination of the following optional parameters
in any order, except that the first one must be the
channel
parameter which names it. No two
channels may have the same name.
channel
string the name of the feature corresponding to this fixtures DMX channel, up to five
characters.
For example: color, gobo, iris, prism, etc.
short
switch
yes
if the feature’s maximum value is 100,
no
if it is 255. The default is
yes
if
the feature is called
Di
m,
no
otherwise. If the feature is pan or tilt, its maximum value is 9999
regardless of this. Use this if your dimmer channel will be labeled something other than “dim”.
short
toggles the
short
parameter. That is, it sets the feature’s maximum value to 255 if it is
called
Di
m, 100 otherwise.
master
number zero if the feature is unaffected by the
Grand Master
fader, nonzero if it is scaled
by the fader. The fader scales the output only if its DMX value (on a zero to 255 scale, before scaling)
would be less than or equal to this value. Thus, it should be 255 for most dimmers, or 128 for the split
feature on some fixtures that acts like a dimmer from zero to 128, and then strobes beyond that point.
The default is 255 if the feature is called
Di
m, zero otherwise.
master
disables master control if the feature is called
Di
m, enables it over the full range otherwise.
fos
switch
yes
if the full feature range corresponds to a DMX output range of 15 to 255, instead of
the usual zero to 255. This is a special mode used for some FOS fixtures; its default value is
n
o. If this
is specified without a switch, it is turned on.
fos
equivalent to
fos ye
s.
htp
switch
yes
if HTP,
no
if LTP. The default is
yes
if the
feature name is
Di
m,
Shu
t,
Re
d,
Green
or
Blu
e,
no
otherwise.
htp