Allied Telesis AT-2972T/2 User Manual
Page 79
AT-29xx Series Gigabit Ethernet Adapters Installation Guide
79
Note
This parameter is ignored and assumed to be 1 if the line_speed
parameter is set to 0.
full_duplex
This parameter is used together with line_speed to select the speed
and duplex mode of the link. Note that this parameter is ignored if
line_speed is 0. Choose from the following selections.
0 - half duplex
1 - full duplex (default)
rx_flow_control
Enables or disables receiving flow control (pause) frames. This
parameter is used together with auto_flow_control. Choose from the
following selections.
0 - pause receive disabled
1 - pause receive enabled if auto_flow_control is set to 0, or pause
receive advertised if auto_flow_control is set to 1 (default)
tx_flow_control
Enables or disables transmitting flow control (pause) frames. This
parameter is used together with auto_flow_control. Choose from the
following selections.
0 - pause transmit disabled
1 - pause transmit enabled if auto_flow_control is set to 0, or pause
transmit advertised if auto_flow_control is set to 1 (default)
auto_flow_control
Enables or disables Auto-Negotiation of flow control. This parameter is
used together with rx_flow_control and tx_flow_control to determine
the advertised flow control capability. Choose from the following
selections.
0 - flow control Auto-Negotiation disabled
1 - flow control Auto-Negotiation enabled with capability specified
in rx_flow_control and tx_flow_control (only valid if line_speed is
set to 0 or auto_speed is set to 1) (default)
mtu
Enables jumbo frames up to the specified MTU size. The valid range
for this parameter is 1500 to 9000. The default is 1500 which is the
standard Ethernet (non-jumbo) MTU size. Note that the MTU size
excludes the Ethernet header size of 14 bytes. Actual frame size is
MTU size + 14 bytes.