beautypg.com

Allied Telesis AlliedView-EMS 4.0.2 Device-Manager User Manual

Page 49

background image


AlliedView™-EMS 4.0.2 DEVICE MANAGER USER’S GUIDE

Page 49 of 124

Condition - Threshold configured on the variable. If the variable's value exceeds the

threshold, an action is executed. You can configure the type of action to execute

in the User Action tab of the Option menu.

Note

- Current, Max, Min and Average values are zero before the first polling. After the first

polling, they all have the same value. Once the threshold is reached, the corresponding row

is highlighted with a red background. Note that thresholds can only be set for MIB variables

of type GAUGE, INTEGER, COUNTER, GAUGE32, INTEGER32, COUNTER32,

or COUNTER64.

Display Threshold

Add button (Green 'plus' icon)

Adds a new threshold definition.

Remove button (Blue 'X' icon)

Removes the selected threshold.

Edit button ('note and pen' icon)

Edits the selected threshold.

5.2.6 Current Log

Displays the event log. It records events such as Device Manager start up, reception

of traps, or threshold events.