Sampling MIB Variable Name
MIB variable to be monitored. The object type must be one of INTEGER,
COUNTER, GAUGE and TIMETICKS.
Sampling Type
How to compare the sampled value with the threshold. "absolute value" means
comparing the sampled data with the threshold without modification. "delta value"
means comparing the difference between the latest sampled value and the previous
sampled value with the threshold.
Sampling Value
The last sampled value.
Startup Alarm Type
The type of threshold which is applied to the first sampled value after this Alarm
entry becomes valid.
rising alarm
A single RMON event is triggered if the first sampled value is greater than or equal
to the configured rising threshold.
falling alarm
A single RMON event is triggered if the first sampled value is less than or equal
to the configured falling threshold.
rising or falling alarm
A single RMON event is triggered if the first sampled value is greater than or equal
to the configured rising threshold, or if the first sampled value is less than or equal
to the configured falling threshold.
Rising Threshold
The ceiling threshold.
Falling Threshold
The floor threshold.
Rising Event Index
The index of the RMON Event entry which is triggered when the sampled value
rises above the rising threshold.
Falling Event Index
The index of the RMON Event entry which is triggered when the sampled value falls
below the falling threshold.