Per Sample
Displays data which Device Manager got from the RMON agent as it is.
Data sampled by RMON Data displayed by Device Manager
Sample 1 100
100
Sample 2 50
50
Sample 3 250
250
Per Second
Displays "Sampled data / Sampling Interval configured on the RMON agent".
The sampling interval here is the RMON agent's sampling interval, not the interval
configured in Device Manager. In the following example, the RMON agent's sampling
interval is 10 seconds.
Note
- Calculated values are rounded. For example, the Number of Error packets
is usually very small so that the calculated value is likely to be zero.
Data sampled by RMON Data displayed by Device Manager
Sample 1 100
10 (100 / 10)
Sample 2 50
5 (50 / 10)
Sample 3 250
25 (250 / 10)
7.3.7.3 Regist Menu
Add this window to the user-defined User Menu.
7.3.7.4 Save Polling Data
This button opens the Polling Data Save dialog box, used to save collected data to a file.
Specify the name and format of the file in which the data is to be saved. Select a file format
from the options below. To start saving the data, click OK.
When you start saving data, the button's label changes to "Saving polled data". To close the
file and stop saving the data, click the "Saving polled data" button.
CSV Format
Saves the data in comma-separated values (CSV) format.
TAB Format
Saves the data in tab-separated values (TSV) format.
Note
- Only the values of the collected RMON variables are saved. Values Device Manager
calculates from these collected values are not saved.
7.3.7.5 Start Snapshot
Clicking this button opens the Start Snapshot window. Use this window to create an image
of the device, as well as tables or charts representing device information, in HTML format.
Use the 'Browse' button to select the directory or folder where you want to save the
image.