beautypg.com

Table 9. system status led descriptions – Allied Telesis x610 Series Layer 3 User Manual

Page 43

background image

x610 Series Layer 3 Gigabit Ethernet Switches Installation Guide

43

Table 9. System STATUS LED Descriptions

LED

State

Description

FAULT

Off

Indicates normal operation.

Red
Flashing

The switch or management software is
malfunctioning. This LED lights and then turns off
after hardware initializes. The following flash
sequences indicate a hardware-related fault.
After sequences of two or more flashes, the LED
stops briefly, then repeats the sequence. If
multiple faults occur, the LED flashes each
sequence in turn, stops briefly, then repeats the
sequences.

1 Flash

This state is not supported on the x610 Switches.

2 Flashes

One or more than one of the chassis fan rotors or
the pluggable POE chassis power supply fans is
operating below the recommended speed.

3 Flashes

This state indicates a chassis power supply fault
and the chassis is powered by AT-RPS3000
Redundant Power Supply. This indication applies
to all non-POE and POE models.

4 Flashes

This state is not supported on the x610 Switches.

5 Flashes

The RPS3000 is connected to the x610 switch,
but no RPS power is available to be supplied.

6 Flashes

The switch’s temperature has exceeded the
recommended threshold.

MASTER Off

Indicates that the switch is not the Stack Master.

Flashing
Green

Indicates the specific stack member’s ID of the
switch in response to the ‘show stack indicator’
command. The LED will repeatedly flash ‘n’ times
in quick succession, followed by a longer pause,
where n is the stack member's ID.

Solid
Green

Indicates that the switch is the Stack Master.

RPS

Off

No optional redundant power supply is
connected to the switch.

Solid
Green

An optional redundant power supply is physically
connected to the switch and may be powered on
or off.