Starting a Local

Management

Session

The following procedure describes how to connect an RJ-45 cable to an
x610 switch. For information about how to log onto the AlliedWare Plus

Operating System Software, see the AlliedWare Plus

Operating System

Software Reference Guide.

To start a local management session on the unit, perform the following
procedure:

1. Connect the RJ-45 end of the management cable included with the

x610 switch to the Terminal Port on the front panel of the switch, as
shown in Figure 77.

22

SFP

23

21

24

15

17

19

21R

16

18

20

22R

24R

23R

1000

/

100

SD

STATUS

FAULT

MASTER
RPS
PWR

PRES

MSTR

L/A

L/A

CLASS

1

LASER PRODUC

T

1
2

STACK

BUSY

READ

Y

FAULT

CON

SOLE

2076

Figure 77. Connecting the Management Cable to the RJ-45 Terminal Port

on the Switch

2. Connect the other end of the cable to an RS-232 port on a terminal or

a personal computer with a terminal emulation program.

3. Configure the terminal or terminal emulation program as follows:

Baud rate: Default is 9600 bps (Range is 9600 to 115200 bps)

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None

Note

The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.