Starting a local management session, Data bits: 8, Parity: none – Allied Telesis x610 Series Layer 3 User Manual
Page 109: Stop bits: 1

x610 Series Layer 3 Gigabit Ethernet Switches Installation Guide
109
Starting a Local
Management
Session
The following procedure describes how to connect an RJ-45 cable to an
x610 switch. For information about how to log onto the AlliedWare Plus
Operating System Software, see the AlliedWare Plus
Operating System
Software Reference Guide.
To start a local management session on the unit, perform the following
procedure:
1. Connect the RJ-45 end of the management cable included with the
x610 switch to the Terminal Port on the front panel of the switch, as
shown in Figure 77.
22
SFP
23
21
24
15
17
19
21R
16
18
20
22R
24R
23R
1000
/
100
SD
STATUS
FAULT
MASTER
RPS
PWR
PRES
MSTR
L/A
L/A
CLASS
1
LASER PRODUC
T
1
2
STACK
BUSY
READ
Y
FAULT
CON
SOLE
2076
Figure 77. Connecting the Management Cable to the RJ-45 Terminal Port
on the Switch
2. Connect the other end of the cable to an RS-232 port on a terminal or
a personal computer with a terminal emulation program.
3. Configure the terminal or terminal emulation program as follows:
Baud rate: Default is 9600 bps (Range is 9600 to 115200 bps)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.