beautypg.com

Allied Telesis x610 Series Layer 3 User Manual

Page 104

background image

2205

A

A

A

T

-PWR250

DC OUT
FAULT

+

-

6A

40-60VDC

FOR CENTR

ALIZED DC POWER

C

ONNECTION,

INST

ALL ONL

Y IN A

ON

OFF

+48 VDC Positive

Ground

-48 VDC Negative

Terminal

Terminal

Terminal

8mm ±1mm

(0.31in. ±0.039in.)

Chapter 4: Cabling the Network Ports

104

Figure 71. DC Terminal Block on the DC AT-PWR250 Power Supply

Module

4. With a 14-gauge wire-stripping tool, strip the three wires in the tray

cable coming from the DC input power source to 8mm

± 1mm (0.31 in.,

± 0.039 in.), as shown in Figure 72 on page 104.

Warning

Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation.  E10

Figure 72. Stripped Wire

5. Insert the power supply ground wire into the middle connector of the

DC terminal and tighten the connection with a flathead screwdriver, as
shown in Figure 73 on page 105.