beautypg.com

Dc terminal block, Stripped wire – Allied Telesis 8100S Series User Manual

Page 98

background image

Chapter 6: Powering On and Verifying the Stack

98

Figure 41.

DC Terminal Block

3. With a 14-gauge wire-stripping tool, strip the three wires in the tray

cable coming from the DC input power source to 8mm

± 1mm (0.31 in.,

± 0.039 in.), as shown in Figure 42 on page 98.

Warning

Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation.

 E10

Figure 42.

Stripped Wire

4. Insert the power supply ground wire into the middle connector of the

DC terminal and tighten the connection with a flathead screwdriver, as
shown in Figure 43 on page 99.

Warning

When installing this equipment, always ensure that the power supply
ground connection is installed first and disconnected last.

 E11

Positive

Ground

Negative

Terminal

Terminal

Terminal