FRONT PANEL KEYS

The F1 key is pressed to exit (or escape) directly to the start of the

Display Loop. While in the Display Loop, the F1 key can be pressed to

activate its programmed function.

The Loop key is pressed to advance to the next parameter, to activate

a changed selection/value, and when held for three seconds, enter the

Hidden Loop.

The Arrow keys are used to scroll through parameter selections/

values and in the Configuration Loop they are used to scroll to the

appropriate Parameter Module.

4.0 r

evieWing

the

F

ront

K

eyS

And

d

iSplAy

L

A

BJ

2

2

1

O

O

1

A

A

R

MAN

% W

P

%

TOP DISPLAY

BOTTOM DISPLAY

ILLUMINATES WHEN OUTPUT POWER

PERCENTAGE IS SHOWN.

ILLUMINATES WHEN CONTROLLER

IS IN MANUAL MODE.

ILLUMINATES WHEN PERCENT

IS SELECTED. (P16 ONLY)

ILLUMINATES WHEN °F or °C

IS SELECTED. (T16 ONLY)

DISPLAYS TEMPERATURE/PROCESS VALUE.

ALSO DISPLAYS PARAMETER NAME IN

CONFIGURATION LOOP.

DISPLAYS SETPOINT OR

% OUTPUT POWER.

ALSO DISPLAYS PARAMETER NAME AND VALUE

IN DISPLAY AND HIDDEN LOOPS OR

PARAMETER VALUE IN CONFIGURATION LOOP.

ILLUMINATES WHEN COOLING

(SECONDARY) OUTPUT IS ACTIVE.

ILLUMINATES WHEN MAIN

CONTROL OUTPUT IS ACTIVE.

ILLUMINATES WHEN ALARM 2

OUTPUT IS ACTIVE.

ILLUMINATES WHEN ALARM 1

OUTPUT IS ACTIVE.

FLASHES WHEN RAMPING

SETPOINT IS ACTIVE.

5.0 p

rogrAmming

: d

iSplAy

l

oop

DISPLAY LOOP

Note: Setpoint and Output Power are the only parameters visible in the Display Loop with Factory Settings. The remaining parameters can

be selected for the Display Loop within Module 3.

Parameter availability is model and programming dependent.

DISPLAY LOOP

At power up, all display segments light, and then the programmed input type

and the controller’s software version will flash. Then the Temperature/Process

Value is shown in the top display, and the Setpoint Value is shown in the bottom

display. This is the Display Loop. If the Setpoint is hidden or locked, the Display

Loop will default to Output Power. If Output Power is also hidden or locked out,

the bottom display is blank. During programming, the F1 key can be pressed to

return the controller to this point. (Only in the Display Loop will the F1 key

perform the user

F1In

function programmed in Input Module

1I

.)

When the A is pressed the controller advances to the next parameter in the

Display Loop. Except for Setpoint and % Output Power, the bottom display

alternates between the parameter name and its selection/value. The arrow keys

are pressed to change the selection/value for the shown parameter. The new

selection/value is activated when the A is pressed. Display Loop parameters

may be locked out or hidden in Lockout Module

3-LC.

Some parameters are

model and programming dependent.

FRONT DISPLAY

ENDS AND RETURNS TO START OF DISPLAY LOOP.

ADVANCES TO NEXT PARAMETER.

CHANGES SELECTION/VALUE.

240

°F

AL-1

TOP DISPLAY

TEMP/PROCESS

BOTTOM DISPLAY

PARAMETER

SELECTION/VALUE

0

F1

This manual is related to the following products: