background image

36

Chapter 4

Troubleshooting and Maintenance

Vantage Vue Troubleshooting Guide

While your Vantage Vue weather station is designed to provide years of trouble-free operation,
occasional problems may arise. If you are having a problem with your station, please consult
this troubleshooting guide before calling Davis technical support. You may be able to quickly
solve the problem yourself. Please see “Contacting Davis Technical Support” on page 52.

Note:

Refer to the ISS Installation Manual for additional troubleshooting information.

T

ABLE

4-1: T

ROUBLESHOOTING

G

UIDE

Problem

Solution

Display

Display is blank

Unit is not receiving power. Check the power adapter connections
and/or replace batteries.

Display shows dashes
in place of weather data

ISS is not transmitting. See ISS manual.

Console not receiving - See “Troubleshooting Reception
Problems” on page 37.

A reading has exceeded the limits indicated in the
specifications table.Calibration numbers may be causing
readings to exceed display limits. Check calibration number
and adjust if necessary.

Console is sluggish or
does not work at low
temperatures

The console and display may not work below 32° F (0° C). Use an
external temperature sensor in low-temperature locations or install
the console indoors.

Display “locks up”

Reset the console by removing AC and battery power then
restoring power. If this occurs frequently in an AC-powered
console, plug the AC power adapter into a surge suppressor, or
use batteries. (They will last up to a year.)

Humidity

Inside humidity seems
too high or too low

Make sure the console is not near a humidifier or dehumidifier.
Check calibration number and adjust if necessary. If inside
humidity is low, and inside temperature is too high, see
temperature, below. Turn off the console backlight.

Wind

Wind speed reading
seems too low.

Remove wind cups and check for friction sources. Check the ISS
location. Is it sheltered from the wind? See ISS manual for
additional wind speed troubleshooting information.

Wind speed reads 0
either all the time or
intermittently

The problem may be with the wind cups. Test by spinning. Check
the corresponding wind fields in the diagnostic screens and call
technical support. (See “Screen 1: Statistical Diagnostic Screen”
on page 39.)

Wind reading is dashed
out

Check reception. See Reception Problems below.

Dew

Dew Point reading
seems too high or too
low

Check calibration numbers for temperature. Dew point depends on
outside temperature and humidity. Make sure both sensors are
working.