Recommendations

Addressing performance issues with no hardware upgrade recommendation

The following scenario provides an example of a recommendation that does not suggest additional
hardware.
In the following figure, a major status icon appears for the processors. Online Analysis recommends
that you determine if the processing load can be distributed more evenly across the available
processors.

This recommendation indicates that more than one logical processor exists in the system and at
least one processor is not fully utilized. This recommendation demonstrates not only a solution
without involving hardware, but also the specificity of Performance Management. Online Analysis
recommendations for these types of performance issues are component-specific.

Performing a static analysis

The following sections provide examples of using static analysis.

General usage

Performance issues are often introduced during system configuration. This condition might be
caused by a planning error, an error in following the prescribed configuration path, or as a result
of the system receiving many updates to a system over time. Regardless of the cause, Performance
Management can analyze static configurations and make suggestions about areas of concern
before a change occurs.
To see a static analysis report:

1.

From the Insight Control/Insight Dynamics console toolbar, click Reports

→Performance

Management

→Static Analysis Report.

2.

Select the pmp-xicc385pe9m server checkbox.

3.

To display the Static Analysis Report for pmpserver, click Generate Report. These results can
be printed from the browser.

Recommendations

69