Scsi drive inventory, Scsi storage enclosure, Scsi storage enclosure status – HP Insight Control User Manual
Page 56
SCSI Drive Inventory
•
Drive Information
Displays a description of the drive, including the size
◦
◦
Displays the hard drive model number
◦
Displays the exact size of the drive as seen by the operating system
•
Configuration Information
Provides a summary of the drive configuration
◦
◦
Displays the name of the Smart Array controller to which it is attached
◦
Displays the location of the hard drive in its enclosure
◦
Displays the array in which the drive is configured
◦
Provides the SCSI protocol negotiated for transfers between this drive and the disk
controller
SCSI storage enclosure
The following information is provided for a SCSI storage enclosure.
SCSI Storage Enclosure Status
•
Transfers/Sec—The average number of transfers on this SCSI bus each second (the sum of
the Disk Transfers/Sec for all hard drives on this bus).
•
MBytes/Sec—The average number of megabytes transferred on this SCSI bus each second
(the sum of the Disk MBytes/Sec for all SCSI drives on this bus).
•
SCSI Utilization %—The average SCSI utilization for this SCSI bus, which is primarily dependent
on the MBytes/Sec, and the SCSI protocol negotiated between the controller and each drive
on the bus. The negotiated SCSI protocol is reported in the hard drive inventory. The valid
SCSI protocols include:
◦
SCSI-1-5 MB/s with 8-bit transfers at 5 MHz (5,000,000 bytes/s)
◦
Fast SCSI-2- 10 MB/s with 8-bit transfers at 10 MHz (10,000,000 bytes/s)
◦
Fast-Wide SCSI-2- 20 MB/s with 16-bit transfers at 10 MHz
◦
Ultra SCSI-3- 20 MB/s with 8-bit transfers at 20 MHz
◦
Wide-Ultra SCSI-3- 40 MB/s with 16-bit transfers at 20 MHz
◦
Wide Ultra2 SCSI- 80 MB/s with 16-bit transfers at 40 MHz
◦
Wide Ultra3 SCSI- 160 MB/s with 16-bit transfers at 80 MHz
◦
Ultra320 SCSI- 320 MB/s with 16-bit transfers at 160 MHz
SCSI storage enclosure performance is determined by the SCSI Utilization %.
56
Measurement parameter matrix