14 blade management commands, Set nic, Set blade powerdelay – HP Integrity Superdome 2 Server User Manual
Page 97: Set blade uid, Set nic set blade powerdelay set blade uid

14 Blade management commands
SET NIC
•
Command:
SET NIC {AUTO | FORCED}
•
Description:
Configures the external NIC for auto-negotiation or forced link settings.
•
Access level/Bay level:
OA Administrator
•
Restrictions:
None
SET BLADE POWERDELAY
•
Command:
SET BLADE POWERDELAY {ALL | <bay number> [{ - | , } <bay number>]}
{number of seconds to delay power | NOPOWERON}
NOTE:
SERVER
is a valid alias for BLADE.
•
Description:
Set the PowerDelay status of the specified server or range of servers. If the delay is zero, the
delay has no effect on the device. If the delay is NOPOWERON, then the device cannot power
on until all devices have completed the delays.
•
Access level/Bay level:
Administrator
◦
◦
Bay specific
•
Restrictions:
You must have access to the specified bay number.
SET BLADE UID
•
Command:
SET BLADE UID {ALL | <bay number> [{ - | , } <bay number>]} {ON | OFF}
NOTE:
SERVER
is a valid alias for BLADE.
•
Description:
Turns a server blade UID LED on or off
•
Access level/Bay level:
All
◦
◦
Bay specific
•
Restrictions:
You must have access to the specified bay number.
SET NIC