beautypg.com

Show interconnect status, Show xfm info, Show interconnect status show xfm info – HP Integrity Superdome 2 Server User Manual

Page 115

background image

1 Cisco Catalyst Blade Switch 3120 Disabled

2 Absent Disabled

3 Absent Disabled

4 Absent Disabled

SHOW INTERCONNECT STATUS

Command:

SHOW INTERCONNECT STATUS {ALL | <bay number>
| <bay number>-<bay number>}

Description:

Displays interconnect status information; UID state and health state

Access level/Bay level:

All

Bay specific

Restrictions:

You must have explicit access to a bay given by the ASSIGN INTERCONNECT command.

Example:

OA-0018FE27577F> SHOW INTERCONNECT STATUS ALL

Interconnect Module #1 Status:

Status : OK

Thermal: OK

CPU Fault: OK

Health LED: OK

UID: Off

Powered: On

Diagnostic Status:

Internal Data OK

Management Processor OK

Thermal Warning OK

Thermal Danger OK

I/O Configuration OK

Device Failure OK

Device Degraded OK

Interconnect Module #2 Status:

Interconnect Module Type: No Interconnect Module Installed

Interconnect Module #3 Status:

Interconnect Module Type: No Interconnect Module Installed

Interconnect Module #4 Status:

Interconnect Module Type: No Interconnect Module Installed

SHOW XFM INFO

Command:

SHOW XFM INFO { ALL | <xfm_number> {[ - | , ] <xfm_number>} }

SHOW INTERCONNECT STATUS

115