beautypg.com

Show interconnect port map, Show interconnect powerdelay – HP Integrity Superdome 2 Server User Manual

Page 114

background image

SHOW INTERCONNECT PORT MAP

Command:

SHOW INTERCONNECT PORT MAP {ALL | <bay number>
| <bay number>-<bay number>}

Description:

Displays the port mapping for the interconnect specified by the bay number

Access level/Bay level:

All

Bay specific

Restrictions:

You must have explicit access to a bay given by the ASSIGN INTERCONNECT command.

Example:

OA-0018FE27577F> SHOW INTERCONNECT PORT MAP ALL

1: Cisco Catalyst Blade Switch 3120X for HP w/ IP Base

Type: Ethernet

Width: Single

Status: OK

Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Status OK OK OK OK

Blade 2A 7 2B 7

Mezz/Nic NI NI NI NI

Port 1 1 1 2

2.

3.

4.

SHOW INTERCONNECT POWERDELAY

Command:

SHOW INTERCONNECT POWERDELAY {ALL | <bay number> [{ - | , }
<bay number>]}

Description:

Displays the PowerDelay status for the specified interconnects or range of interconnects

Access level/Bay level:

All

Bay specific

Restrictions:

None

Example:

OA-0018FE27577F> SHOW INTERCONNECT POWERDELAY ALL

Current PowerDelay Status: Not in Progress

Bay Device PowerDelay State Delay (seconds)

--- -------------------------------- ------------

114