SET ENCLOSURE SERIAL_NUMBER

Command:

SET ENCLOSURE SERIAL_NUMBER "<serial number>"

Description:

Sets the enclosure serial number.

Access level/Bay level:

OA Administrator

Restrictions:

Must be 10 characters in length and includes all alphanumeric, underscore (_), and dash (-)
characters.

SET ENCLOSURE UID

Command:

SET ENCLOSURE UID {ON | OFF}

Description:

Turns the UID LED of the enclosure on or off.

Access level/Bay level:

OA Administrator, OA Operator

Restrictions:

None

SET IOX UID

Command:

SET IOX UID { ALL | <iox number> [{-|,}] <iox number>]} {ON | OFF}

Description:

Turns the UID LED of the specified IOX enclosures on or off.

Access level/Bay level:

OA Administrator, OA Operator, OA user

Restrictions:

You must be logged on to the monarch OA to perform this command.

SET LLF INTERVAL

Command:

SET LLF INTERVAL <seconds>

Description:

Set the Link Loss Failure Interval

Access level/Bay level:

Operator, Administrator

Restrictions:

Must have OA permission to perform this command.