beautypg.com

Show blade temp – HP Integrity Superdome 2 Server User Manual

Page 103

background image

Access level/Bay level:

All

Restrictions:

None

Example:

sphere-oa2> show blade status 1
Blade #1 Status:
Power: On
Current Wattage used: 1325 Watts
Health: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Management Processor OK
I/O Configuration OK
Power OK
Cooling OK
Device Failure OK
Device Degraded OK
Device Info OK
Firmware Mismatch OK
PDHC OK
Indicted OK

SHOW BLADE TEMP

Command:

SHOW BLADE TEMP {ALL | <bay number> [{ , | - } <bay number>]}

NOTE:

SERVER

is a valid alias for BLADE.

Description:

Displays the temperature sensor information for a specified blade or range of blades

Access level/Bay level:

All

Bay specific

Restrictions:

You must have access to the specified bay number.

Example:

sphere-oa2> show blade temp 1

Device Bay #1 Temperature Information
Locale Status Temp Caution Critical
----------------------------------- ------ -------- ------- --------
Memory Zone OK 25C/ 77F 40C 50C
Memory Zone OK 25C/ 77F 40C 50C
Memory Zone OK 26C/ 78F 40C 50C
Memory Zone OK 24C/ 75F 40C 50C
Ambient Zone OK 23C/ 73F 32C 37C
System Zone OK 29C/ 84F 65C 70C
System Zone OK 27C/ 80F 65C 70C
System Zone OK 26C/ 78F 65C 70C

SHOW BLADE TEMP 103