Access level/Bay level:
All
•
Restrictions:
Must be in the Health Repository viewer.
•
Example:
myhost HR> show deconfig
System Acquittal History - Mon May 18 16:11:28 2009
--------------------------------------------------
FRU Type: Blade DIMM
Location: 0x0100FF0200160A74
Timestamp: Mon May 18 16:11:19 2009
Indictment State: Indicted
Requested Deconfig State: Configured
Current Deconfig State: Deconfigured
FRU Type: CPU Socket
Location: 0x0100FF01FF00FF11 enclosure1/blade1/socket0
Timestamp: Mon May 18 16:11:19 2009
Indictment State: Indicted
Requested Deconfig State: Configured
Current Deconfig State: Deconfigured
enclosure1/blade2/socket0/dimm16
--- end report --- 2 records shown
NOTE:
DIMMs may be deconfigured without being indicted. Some faults isolated to CPU sockets
or blades may require deconfiguration of whole or portions of memory subsystems. This is
accomplished by physically deconfiguring the DIMMs supported by that resource.
SHOW HR
•
Command:
SHOW HR
•
Description:
Launches the Health Repository viewer
•
Access level/Bay level:
All
•
Restrictions:
You must be logged on to the monarch OA to perform this command.
SHOW INDICT
•
Command:
SHOW INDICT
•
Description:
Lists all currently indicted components for the complex, with the following information:
◦
Component Type
◦
Physical Location
◦
Timestamp of the indictment
SHOW HR
159