beautypg.com

Show hr, Show indict, Show hr show indict – HP Integrity Superdome 2 Server User Manual

Page 159

background image

Access level/Bay level:

All

Restrictions:

Must be in the Health Repository viewer.

Example:

myhost HR> show deconfig
System Acquittal History - Mon May 18 16:11:28 2009
--------------------------------------------------

FRU Type: Blade DIMM
Location: 0x0100FF0200160A74
Timestamp: Mon May 18 16:11:19 2009
Indictment State: Indicted
Requested Deconfig State: Configured
Current Deconfig State: Deconfigured

FRU Type: CPU Socket
Location: 0x0100FF01FF00FF11 enclosure1/blade1/socket0
Timestamp: Mon May 18 16:11:19 2009
Indictment State: Indicted
Requested Deconfig State: Configured
Current Deconfig State: Deconfigured

enclosure1/blade2/socket0/dimm16
--- end report --- 2 records shown

NOTE:

DIMMs may be deconfigured without being indicted. Some faults isolated to CPU sockets

or blades may require deconfiguration of whole or portions of memory subsystems. This is
accomplished by physically deconfiguring the DIMMs supported by that resource.

SHOW HR

Command:

SHOW HR

Description:

Launches the Health Repository viewer

Access level/Bay level:

All

Restrictions:

You must be logged on to the monarch OA to perform this command.

SHOW INDICT

Command:

SHOW INDICT

Description:

Lists all currently indicted components for the complex, with the following information:

Component Type

Physical Location

Timestamp of the indictment

SHOW HR