Zoning limits and properties

Zoning limits vary depending on the firmware installed on the switch. To view zoning limits and properties
on a switch:

1.

Select

Zoning > Edit Zoning to open the Edit Zoning dialog.

2.

Choose one of the following:
• Right-click on the top zonesets entry, a zone set, a zone, or a zone member in the zone sets tree (left

windowpane). Select

Properties in the popup menu.

• Select the top zone sets entry, a zone set, a zone, or a zone member in the zone set tree (left

windowpane). Select

Edit > Properties.

3.

View the zoning limits and properties information in the Properties dialog.

4.

Click

OK to close the Properties dialog.

The zoning limits and definitions are:

MaxZoneSets is 1. The maximum number of zone sets that can be configured on the switch. This will be
enforced during the configuration of zoning and during a zoning database merge from the fabric.

MaxZones is 2047. The maximum number of zones that can be configured on the switch. This will be
enforced during the configuration of zoning and during a zoning database merge from the fabric.

MaxTotalMembers is 10,000. The maximum number of total zone members that can be configured on
the switch. This will be enforced during the configuration of zoning and during a zoning database
merge from the fabric.

MaxZonesInZoneSets is 2047. The maximum number of zone linkages to zone sets that can be
configured on the switch. This will be enforced during the configuration of zoning and during a zoning
database merge from the fabric. Every time a zone is added to a zone set this constitutes a linkage.

MaxMembersPerZone is 4096. The maximum number of zone members that can be added to any zone
on the switch. This will be enforced during the configuration of zoning and during a zoning database
merge from the fabric.