Using flexfabric modules – HP Virtual Connect Enterprise Manager Software User Manual
Page 58
Resynchronizing a VC Domain with Configuration Mismatch
Resynchronizing a VC Domain forces VCEM to verify that the VC Domain is still compatible with
the VC Domain Group configuration without removing and adding that VC Domain to a VC Domain
Group. The VC Domain configuration conforms to the same requirements when you add a VC
Domain into a VC Domain Group for the first time.
There are two ways a VC Domain with a configuration mismatch is resynchronized:
•
Manually resynchronizing:
1.
Go to the VC Domains tab.
2.
Select the VC Domain with Configuration Mismatch status.
3.
Click VC Domain Maintenance. A dialog box showing the VC Domain to be resynchronized
appears.
4.
Click OK to confirm. The Virtual Connect Enterprise Manager is executing
the request
message appears with a job ID code.
5.
Click OK to go to the Jobs page and monitor job progress.
•
Automatically resynchronizing:
If VCEM detects a configuration mismatch, it starts auto resynchronization when you perform
a server profile operation.
displays restoring the VC Domain configuration in the
job details.
Figure 23 Job details
Replacing the HP 1/10 Gb VC-Enet or the HP 1/10 Gb-Enet modules
To upgrade the HP 1/10 Gb VC-Enet module or the HP 1/10 Gb-Enet module to use the HP VC
Flex-10/10D module see sections
“Replacing VC Ethernet modules with FlexFabric modules in an
existing VCEM managed VC Domain” (page 59)
or
“Replacing VC Ethernet in interconnect bays
three to eight with FlexFabric in an existing VCEM managed VC Domain” (page 60)
.
Using FlexFabric modules
This section describes scenarios to add or replace existing Ethernet and FC modules with FlexFabric
modules.
58
Managing VC Domains