Front heater
Print heater
Rear heater
Preset temperature
AAA
BBB
CCC
Current temperature
XXX
YYY
ZZZ
U stands for the temperature unit: C (Celsius) or F (Fahrenheit).
The temperature is measured every 5 seconds and refreshed.
Display — heater on
When each heater is heated, a plus sign (+) is displayed in place of the unit of each heater current
temperature on the second line. The unit display is restored at the completion of heating. In the display
example shown above, the front heater is heated.
Display — heater off
OFF is displayed in the setup temperature display area of the heater that is turned off. The temperature
unit of the heater that is turned off is not displayed. The current temperature area is displayed as it is.
Display — heater AC power is turned off
TURN ON HEATER POWER SWITCH is displayed on the front panel.
Heater parameter setup mode
This mode is used when the operator sets the heater control system parameters.
Setup items and parameters
The setup items and parameters are listed in the table below.
No.
Item
Item display
(upper line)
Parameters
display (lower
line)
Description
Initial value
1
Temperature unit
UNIT
CELSIUS
FAHRENHEIT
–
CELSIUS
174