Heater preset temperature by medium – HP Designjet 9000s Printer series User Manual
Page 181
●
Front panel display (when the heater is turned on):
●
Upper line: preset temperature for each heater
●
Lower line: current temperature for each heater
●
Front panel display (when the heater is turned off):
●
Upper line: OFF for each heater
●
Lower line: current temperature for each heater
The default temperature range is set between 15 °C and 55 °C.
Heater preset temperature by medium
The heater preset temperature for each media type is listed below. Preset the heater temperature
according to the media you use.
Medium
Media type
Front
Rear
Print mode
Glossy vinyl
chloride
Glossy
45°C
40°C
45°C
4-pass
bidirectional
Matte vinyl
chloride
Matte
45°C
40°C
45°C
4-pass
bidirectional
Banner
Banner
45°C
40°C
45°C
4-pass
bidirectional
We recommend that the front heater, the print heater and the rear heater be set to lower than 50 °C, 45 °
C and 50 °C, respectively. When the print heater is set to higher than 45 °C, we recommend setting the
printhead motion mode to HIGHLIGHT.
NOTE When the print heater temperature is set too high, fixing of the ink on the media is
improved, but media wrinkle or mat print may be caused. Adjust heater temperature according
to the media type and environmental temperature.
When the print heater temperature is set to high, the printer may print at low speed to ensure
stable print quality.
Set the front/rear heater temperature 5 °C higher than the print heater temperature. Bad
temperature balance between the front/rear heater and print heater may cause the media to
wrinkle.
ENWW
Heater temperature settings
171
Tell me about
t
h
e heat
ers