Correctable errors, Power-on messages, Integrated management log – HP ProLiant DL380 G5 Server User Manual
Page 78: Remote-insight board event log
•
Server Manager Failure—An error occurred in the server interface with the Server Manager.
•
UPS A/C Line Failure/Shutdown or Battery Low—The device has initiated a UPS or operating system shutdown,
or the battery is almost depleted after an AC line failure.
The Last Failure Message on this window displays the last failure message associated with a critical error.
Correctable errors
This alarm indicates that a block of memory has failed or is failing and might need to be replaced. This condition is
generally non-critical because the memory controller can correct the problem. However, this type of error indicates
that a memory component is failing or has failed in the system issuing the alarm. The system continues to correct any
errors it can.
Memory errors are corrected by the ECC memory subsystem when they occur. If these errors increase, correct the
problems as soon as possible. Further degradation of the memory components might occur, and then errors can no
longer be correctable.
Power-On Messages
The Power-On Messages section displays the Power-On messages logged when the device was turned on. For a
listing of possible Power-On error messages and their meanings, see the device documentation. Click the Clear
Power-On Message button to clear the Power-On message log. This button is only available if there are messages to
clear.
Integrated Management Log
The Integrated Management Log records system events, critical errors, power-on message errors, and memory errors.
The log also records catastrophic hardware and software errors that typically cause a system to fail. This information
helps to quickly identify and correct the problem and minimize downtime.
Each event log entry has a status to identify the severity of the event:
•
Informational—General information about a system event.
•
Repaired—An entry has been repaired. Users must mark entries as repaired.
•
Caution—A non-fatal error condition has occurred.
•
Critical—A component of the system has failed.
If any events in the log have a condition of Caution, the overall log condition is marked as degraded. If Critical
events exist in the log, the overall log condition is marked as failed.
To clear a degraded or failed event log, repair the condition that caused a log entry to be generated, and then mark
the log entry as repaired. Perform the following steps:
1.
Highlight the log entries in the Integrated Management Log.
2.
Click the Mark Repaired button. This button is located at the bottom of the Integrated Management Log section
of the Web browser.
IMPORTANT:
To be able to mark log entries as corrected, agents must have sets enabled and the SNMP
Community string must be correct.
IMPORTANT:
The Monitor and Control community strings for the device is required. The HP Insight
Management Agents and HP Systems Insight Manager uses these community strings to communicate with the
OS SNMP service. If a Control community string is not created, it is not possible to perform certain operations,
such as clearing the Integrated Management Log or changing agent configuration settings.
The Description column gives a brief description of the error or event. The Update Time column contains the last time
this log was updated. The Status column contains the status of the log entry.
Remote-Insight Board event log
The Event Log section displays the list of events stored in the Remote-Insight Board event log. A user with the
appropriate authority can clear these events. Each event includes the following information:
•
Index—Displays a numeric index for each event.
•
Time of Event—Displays the time the event occurred.
•
Description—Displays a text description of the event.
Agent information 78