HP ProLiant DL380 G5 Server User Manual
Page 37
•
Firmware Primary/Secondary—The array controller is using a primary/secondary algorithm implemented in
the controller firmware and the operating system driver.
•
Unknown—Indicates that the Storage Agents cannot determine the redundancy type for the controller. You
may need to upgrade the Storage Agents.
•
Redundancy Error—Displays the redundancy error for the controller. The following values are valid:
•
No Failure—No failures have been detected.
•
No Redundant Controller—No redundant controller is installed.
•
Different Hardware—The other controller indicates a different hardware model.
•
No Link—A link to the other controller could not be established.
•
Different Firmware—The other controller indicates a different firmware version.
•
Different Cache—The other controller indicates a different cache size.
•
Other Cache Failure—The other controller indicates a cache failure.
•
No Drives—This controller cannot see any attached drives, but the other controller can.
•
Other No Drives—This controller can see the attached drives, but the other controller cannot.
•
Unsupported Drives—One or more attached drives has been determined to be incapable of properly
supporting redundant controller operation.
•
Expand in Progress—An expand operation is in progress. Redundant operation not supported until the
expand operation is complete.
•
Unknown—Indicates that the Storage Agents are unable to determine the redundancy error for the
controller. You may need to upgrade the Storage Agents.
•
Firmware Version—L
ists the firmware version of the array controller. This value can be used to help
identify a particular revision of the controller.
•
Product Revision—Displays the revision of the array controller board. This value can be used to help identify a
particular revision of the controller.
•
Serial Number—Displays the serial number for the array controller. Use this number for identification purposes.
•
Processor Usage—Displays the total percentage of the processor usage, expressed as a number from 0 to 100
inclusive.
•
Command Count—Displays the total number of read and write commands processed in this sample. This value
is expressed as read and write commands per second.
•
Command Latency—Displays the average command latency for this sample in 1/100,000 of a second units.
•
ADG Enabler Status—Displays the array controller RAID ADG Enabler Module status. The module enables
advanced controller features such as Advanced Data Guarding. The following values are valid:
•
Not Supported—Indicates that the RAID ADG Enabler Module is not supported by this type of controller.
•
Not Present—Indicates that the RAID ADG Enabler Module is not present or is not accessible.
•
Fully Functional—Indicates that the RAID ADG Enabler Module is functional and accessible.
•
Bad Signature—Indicates that the RAID ADG Enabler Module has an incorrect signature.
•
Bad Checksum—Indicates that the RAID ADG Enabler Module checksum failed.
•
Present - Upgrade Firmware—Indicates that the RAID ADG Enabler Module is installed, but a firmware
upgrade is required to make it fully functional.
•
Unknown—Indicates that the Storage Agents do not recognize the RAID ADG Enabler Module. You may
need to upgrade the Storage Agents.
•
Daughter Board Type—D
isplays the type of daughter board installed on the array controller. The
following values are valid:
•
Not Supported—Indicates that the array controller does not support daughter boards or it does not support
daughter board identification.
•
Not Present—Indicates that a daughter board is not installed on the array controller.
•
SCSI—Indicates that a SCSI daughter board is installed on the array controller.
•
Fibre—Indicates that a Fibre daughter board is installed on the array controller.
•
Array—Indicates that an Array Expansion Module is installed on the array controller.
•
Unknown—Indicates that the daughter board type is not recognized. You may need to upgrade the Storage
Agents.
•
Rebuild Priority—D
isplays the logical drive rebuild priority of the controller. The following values are
valid:
•
Low—Indicates the rebuild priority is low.
•
Medium—Indicates the rebuild priority is medium.
Agent information 37