beautypg.com

Cluster interconnect, Cluster software, Sub system classification – HP ProLiant DL380 G5 Server User Manual

Page 23: Power subsystem

background image

Client/Internal—The network is used to connect client systems and for internal cluster communication.

None—The network is not used by the cluster for communication.

State—Displays the current state of the network, which can be one of the following:

Online—The network is online and functioning normally.

Offline—The network is offline.

Partitioned—The network is operational, but two or more nodes on the network cannot communicate.

Typically, a path-specific problem has occurred.

Unavailable—The network is unavailable to the cluster because the role of the network is None.

Unknown—The network has not yet responded and the exact state is undetermined.

Address Mask—Displays the address mask used by the network in the format specified by the transport type.

Description—Displays the text network description if one was entered.

Cluster interconnect

The Cluster Interconnect section displays the following information about the adapters used for cluster

interconnections:

Network—Displays the name of the network.

Address—Displays the address used by the interconnect in the format specified by the transport type.

Transport—Displays the network transport protocol used by the interconnect.

Node—Displays the name of the system in which the adapter is installed.

Physical ID—Displays the physical identification of the interface card including the name, the slot number, and

base I/O address, if available.

Cluster software

The Cluster Software section displays the file name, version number, and description of the HP Insight Management

Agents cluster software.

Sub system Classification

Power Subsystem

This section displays information about the redundant power supplies. The following entries may be displayed:

Location—Displays the bay where the power supply is located.

Condition—Displays the status of the power supply. The following values are possible:

OK—A power supply is installed and operating normally.

Failed—A power supply is installed and is no longer operating. Replace the power supply.

Not Installed—Nothing is installed in this power supply bay.

Unknown—The Server Agent is unable to determine if this storage system power supply bay is occupied.

Serial Number—Displays the serial number of the power supply. This information can be used for identification

purposes.

Firmware Revision—Displays the firmware revision of the power supply.

Present—Represents whether the power supply is present in the chassis.

Status—Represents the status of the power supply in the chassis. The following values are possible:

No Error

General Failure

Bist Failure

Fan Failure

Temperature Failure

Interlock Open

EPROM Failed

VREF Failed

DAC Failed

RAM Test Failed

Voltage Channel Failed

Agent information 23


This manual is related to the following products: