IMPORTANT:
To mark entries as corrected, the agents must have sets enabled and the SNMP Community
string must be correct.
The following list describes errors that might be logged. If any of these errors occur, run System Diagnostics on the
system or see the software documentation.
•
Abnormal Program Termination—A device has detected a fatal software error resulting in a device failure.
•
ASR Base Memory Parity Error—The system detected a data error in base memory following a reset because an
ASR timeout.
•
ASR Extended Memory Parity Error—The system detected a data error in extended memory following a reset
because an ASR timeout.
•
ASR Memory Parity Error—The system ROM was unable to allocate enough memory to create a stack. It was
unable to put a message on the screen or continue booting the server.
•
ASR Reset Limit Reached—The maximum number of system resets has been reached. The System Configuration
utilities are loaded.
•
ASR Reset Occurred—No error data is logged.
•
ASR Test Event—An ASR Test Event was generated by the user through the system utilities. No action is required
because the event was user-generated to test the ASR configuration.
•
ASR Timeout NMI—The server has generated an ASR NMI because the ASR timer has not been refreshed. This
generally indicates a driver has not relinquished control of the processor causing a server failure. The resulting
ASR NMI was generated to log this event.
•
CPU Internal Corrected Error Threshold Exceeded—The system has detected that a processor has exceeded the
threshold for the number of internal ECC cache errors.
•
CPU Processor Power Module Failed—The system has detected that a processor’s power module has failed.
•
Critical Temperature—The system’s critical temperature has been exceeded and auto shutdown has been
initiated.
•
Error Detected On Bootup—The system detected an error during the Power-On Self-Test (POST).
•
Exception—The processor has detected a critical exception resulting in a device failure.
•
Fan Failure—The system or processor fan failed.
•
NMI-Processor Local Error—The processor experienced a fatal error resulting in a device failure.
•
NMI-Expansion Board Error—A board on the expansion bus indicated an error condition causing a device
failure.
•
NMI-Expansion Bus Arbitration Error—Memory refresh cycles were delayed, potentially leading to data loss.
The error results in a system failure.
•
NMI-Expansion Bus Master Time-out—A bus master expansion board in the indicated slot did not release the
bus after its maximum time resulting in a device failure.
•
NMI-Expansion Bus Slave Time-out—A board on the expansion bus delayed a bus cycle beyond the maximum
time resulting in a device failure.
•
NMI-Failsafe Timer Expiration—The software was unable to reset the system failsafe timer, resulting in a system
failure.
•
NMI-Processor Address Error 1—A processor internal address parity checking error occurred, resulting in a
device failure.
•
NMI-Processor Address Error 2—The processor detected an address parity error during an inquire cycle.
•
NMI-Processor Cache Parity Error—A data error occurred within the processor cache, resulting in a system
failure.
•
NMI-Processor Internal Error 1—A processor internal parity error occurred, resulting in a device failure.
•
NMI-Processor Internal Error 2—The processor detected an internal parity error or a functional redundancy
error.
•
NMI-Processor Parity Error—The processor detected a data error resulting in a device failure.
•
NMI-Software Generated Interrupt—Software indicated a system error resulting in a system failure.
•
NMI-System Concurrency Error—A potential error condition was detected within the Data Flow Manager,
resulting in a system failure.
•
NMI-Uncorrectable Memory Error—The device experienced an uncorrectable memory parity error resulting in a
device failure.
•
NMI-Unknown Error Type—The device driver does not recognize this NMI. The health driver might need to be
updated.
•
Processor Failure—The processor failed during the POST.
Agent information 77