beautypg.com

HP ProLiant DL380 G5 Server User Manual

Page 61

background image

Vendor—Displays the vendor name for the CD Library. This item can be used for identification purposes.

Model—Displays the model name of the CD Library. This value can be used for identification purposes.

Serial Number—Displays the serial number of the CD Library. This value can be used for identification

purposes.

Firmware Version—Displays the firmware revision of the CD Library.

CD-ROM drive information

Select a CD-ROM drive from the CD Storage System list to display the following information:

Vendor—Displays the vendor name for the CD-ROM drive

Model—Displays the model name of the CD-ROM drive

Firmware Rev—Displays the firmware revision of the CD-ROM drive

LUN—Displays the logical unit number of the CD-ROM drive

Storage systems

Select a storage system item from the SCSI controller submenu to display the following information about ProLiant

Storage Systems.

Box Type—Displays the type of drive enclosure, or box. The following types of enclosures are possible:

External Storage System—Outside the machine.

Internal Storage System—Inside the machine.

Unknown—The Storage Agents do not recognize the drive enclosure. You might need to upgrade your

software.

Vendor—Displays the name of the vendor that produces this drive enclosure or box type. Use this information

for identification purposes.

Model—Displays the model of the storage system. Use this information for identification purposes.

Firmware Revision—Displays the firmware revision of the drive enclosure or box. Use this information for

identification purposes.

Board Revision—Displays the board revision level of this storage system backplane.

Serial Number—Displays the serial number of the drive enclosure or box. Use this information for identification

purposes.

Thermal Status—Displays the temperature status of the drive system. The following values are possible:

OK—The temperature is within normal operating range.

Degraded—The temperature is outside of normal operating range. Be sure the cover is on the ProLiant

Storage System.

Failed—The temperature is outside of normal operating range, and could permanently damage the system.

Ensure that the fans are spinning and check the room temperature.

Unknown—The Storage Agents do not recognize the thermal status. You might need to upgrade your

software.

No Temperature—This server does not support temperature monitoring.

Fan Status—Displays the status of the fan subsystem in the drive enclosure, or box. The following values are

possible:

OK—The fan subsystem is working properly.

Failed

—A fan has failed and there are not enough fans in the fan subsystem to keep the enclosure cool.

Check your fan subsystem as soon as possible. Continued operation might cause failure of the drives.

Degraded—A fan has failed but there are still enough fans in the fan subsystem to keep the enclosure cool.

Unknown—The Storage Agents do not recognize the status of the fan subsystem. You might need to

upgrade your software.

No Fan—This server does not have a fan.

Backplane Speed—Displays the speed of the storage system backplane. The following values are possible:

Ultra3—The storage system is capable of Ultra3 speeds.

Ultra320—The storage system is capable of Ultra320 speeds.

Unknown—The Storage Agents are unable to determine the storage system backplane speed. You might

need to upgrade your software.

Drive Bays—Displays the number of drive bays provided by this storage system. If duplexing hardware is used

with the storage system, the drive bay number is less than the number of physical drive bays in the enclosure.

Duplex Option—Displays the duplex option installed in this storage system. The following values are possible:

Agent information 61


This manual is related to the following products: