Table 28 troubleshooting suspended truecopy pairs, 28 troubleshooting suspended truecopy pairs, Table 28 – HP StorageWorks XP Remote Web Console Software User Manual
Page 143
TrueCopy for z/OS user guide 143
Invalid Port
The specified port is not
configured as an RCP or initiator
port, or this path already exists.
For serial, verify that the correct MCU port is
configured as an RCP and that the correct RCU port is
configured as an LCP.
For Fibre Channel interface, verify that the Fibre
Channel topology settings of the MCU and RCU ports
are correct.
Verify that you entered the correct RCU S/N and SSID
and path parameters (Fibre: MCU port, RCU port, CU
number and Controller ID. Serial: port, link address
and logical address).
Delete the failed path. You may need to change the
minimum paths setting or delete the RCU to delete the
path. Then add the path/RCU using Add Path or Add
RCU.
RCU Port Number
Mismatch
The specified port in the RCU is
physically disconnected from the
MCU.
Verify that you entered the correct RCU port number.
Correct the port number if necessary.
Verify that the MCU and RCU are physically
connected.
For Fibre Channel interface, verify that the Fibre
Channel topology settings of the MCU and RCU ports
are correct.
RCU Port Type
Mismatch
The specified port in the RCU is
not configured as an RCU Target
port.
Verify that the port in the RCU configured as an RCU
Target port. Configure the port as an RCU Target port
if necessary.
Communication
failed.
The MCU connects to the RCU
successfully, but logical
communication time out occurred.
Verify that the RCU port and remote copy connection
hardware (cables and switches) are properly
configured and functioning.
Port Number
Mismatch
The specified port number is not
correct, or the cable is not
connected to the specified port.
Delete the error path.
Verify that you entered the correct port number.
Verify that the cable is connected.
Fibre Remote Copy is
not Supported
The RCU microcode does not
support fibre remote copy.
Install the microcode that supports fibre remote copy
at the RCU.
Communication Error Communication between the
MCU and RCU through the fibre
path timed out.
Delete the failed path.
This path was not established.
Delete the failed path. You may need to change the
minimum paths setting or delete the RCU to delete the
path. Then add the path/RCU using Add Path or Add
RCU.
Table 28
Troubleshooting suspended TrueCopy pairs
Suspend Type Applies to Description
Corrective Action
M-VOL by
Operator
M-VOL
The user suspended the pair from the
MCU using the M-VOL Failure option.
The R-VOL suspend type is by MCU.
Resume the pair from the MCU.
R-VOL by
Operator
M-VOL,
R-VOL
The user suspended the pair from the
MCU or RCU using the R-VOL option.
Resume the pair from the MCU.
Table 27
Troubleshooting RCU path status problems (continued)
Path Status
Description
Corrective Action