8.

From the Select MAC range type list, select whether the MAC address range type is
VCEM-defined, user-defined, or factory-default. You can only select the user-defined option
for MAC range type if a MAC custom range is defined.

9.

From the Select WWN range type list, select whether the WWN address range type is
VCEM-defined, user-defined, or factory-default. You can only select the user-defined option
for WWN range type if a WWN custom range is defined.

NOTE:

After upgrading from VCEM 1.20 or 1.3x to VCEM 6.3, VC Domain Groups that

were using HP-predefined ranges for MAC and WWN addresses will start using VCEM-defined
ranges for new server profiles. VCEM 6.0 and later do not use HP-predefined ranges for MAC
and WWN addresses.

10. Click OK. The Virtual Connect Enterprise Manager is executing the request

message appears.

11. Click OK to go to the Jobs page and monitor job progress.
12. (Optional) After creating a VC Domain Group, from the Systems Insight Manager User and

Authorization page, select the user authorization privileges for that VC Domain Group. See

“Creating a VC Domain Group” (page 42)

for more information.

Maintaining a VC Domain from the VC Domain Groups page

To perform VC Domain maintenance from the VC Domain Groups page:
1.

Select the VC Domain Group on which you want to perform maintenance.

2.

Click VC Domain Maintenance.

3.

Select the target VC Domain within the selected VC Domain Group which will be enabled for
maintenance, and click Next. The VC Domain Maintenance page appears.

4.

To unlock Virtual Connect Manager for domain, network, and storage changes, click Make
changes via VC Manager. Virtual Connect Manager web interface appears in a separate
browser window. The under maintenance status indicates that the VC Domain Group is
temporarily unlocked for domain network and storage.

5.

Using Virtual Connect Manager, log in with full user rights at VC Manager, perform the
necessary changes, and save the changes. VCEM blocks all operations related to the VC
Domain and to its respective VC Domain Group while the VC Domain is under VC Domain
Maintenance. Close the VC Manager web browser and return to the VC Domain Groups
page in VCEM. To confirm changes in VCEM, repeat steps 1 and 2.

6.

Click the Restore configuration check box to enable VCEM to automatically restore the original
VC Domain configuration in case changes cannot be applied to the VC Domain Group.

7.

Select from one of the following options:

Click Complete VC Domain Maintenance to apply the changes.

If VCEM detects that all VC Domains in the group have higher firmware versions than the
VC Domain Group, a warning similar to the following is displayed:

VCEM detected that in addition to completing the VC Domain

Maintenance process, the VC Domain Group firmware mode [{0}] can

be upgraded to [{1}]. Do you want to upgrade the VC Domain Group

firmware mode? Click 'Yes' to upgrade the VC Domain Group firmware

mode in addition to completing the VC Domain Maintenance

operation. Or click 'No' if you want to complete VC Domain

Maintenance operation at this time. You can manually upgrade the

VC Domain Group firmware mode at a later time by selecting

'Upgrade Firmware Mode' on the VC Domain Groups page.

Click Cancel to discard the VC Domain configuration changes. If the VC Domain is not
under maintenance, clicking Cancel closes the user interface pages. The message Virtual

Maintaining a VC Domain from the VC Domain Groups page