beautypg.com

Creating a vc domain group, Creating a vc domain – HP Insight Management-Software User Manual

Page 42

background image

2.

Click Add Key and enter the key string.

3.

Select one or more unlicensed VC Domains.

4.

Click Apply License.

5.

Click OK to validate the key string.

NOTE:

License key fields are case-sensitive

If the key string is valid, the key is added to HP Insight Software.

6.

Click Next to provide VC Domain credentials.

For existing VC Domain Groups:
1.

Select the VC Domain from the VC Domains page, and then click License.

The License Enclosure page appears.

2.

Click Add Key.

3.

Enter the license key string, and then click OK.

If the license key is valid, it is added to System Insight Manager. The License Enclosure
page reappears, displaying the number of available licenses.

4.

Select the VC Domain to which you want to apply the VCEM license.

5.

Click Apply License.

The VC Domains page reappears, displaying an updated informational status of the VC
Domains.

Creating a VC Domain Group

You can create a VC Domain Group by selecting the VC Domains that you want to include in the
new VC Domain Group.

IMPORTANT:

This VCEM operation does not provide a reference to the VC Domain from Systems

Insight Manager. To access this reference, you must correlate the Systems Insight Manager and
Virtual Connect logs. For more information, see

Correlating VCEM operations in Systems Insight

Manager and Virtual Connect logs

.

VCEM supports multienclosure VC Domains. A multienclosure VC Domain has one local enclosure
and up to three remote enclosures.

To manage multienclosure VC Domains in VCEM, you must perform the following steps before you
create a VC Domain Group:
1.

Log in to Virtual Connect Manager.

2.

Find and import a local enclosure, and then select the appropriate Double-dense option.

3.

Skip the Network and Fibre Channel configuration wizards, and then navigate directly to the
VC Domain user interface.

4.

From Virtual Connect Manager, find and import the necessary remote enclosures in the correct
order. For more information on remote enclosures, see the HP Virtual Connect for c-Class
BladeSystem Setup and Installation Guide
at

http://bizsupport1.austin.hp.com/bc/docs/

support/SupportManual/c01732252/c01732252.pdf

.

5.

From Systems Insight Manager, perform a manual discovery of the Onboard Administrator IP
address for all related VC Domain enclosures.

If you are using an HP VC FlexFabric 10 Gb 24-port module, ensure that the module status is
compatible. See

“Upgrading incompatible firmware modes and versions” (page 21)

for more

information.

VCEM cannot manage a VC Domain that has one or more FC modules with an Incompatible status.

42

Managing VC Domains

This manual is related to the following products: