beautypg.com

Backing up and restoring vcem – HP Insight Management-Software User Manual

Page 133

background image

1.

Double-click Add or Remove Programs.

2.

Click Insight Software.

3.

Click Remove.

IMPORTANT:

The uninstall operation does not remove a VCEM folder from installation

directory, such as C:\Program Files\HP\Virtual Connect Enterprise Manager\. The folder is
empty and no system damage or inability to reinstall or upgrade VCEM again in the future
occurs.

Backing up and restoring VCEM

In the event of catastrophic and complete VCEM failure, all server blades continue to operate, and
the integrity of the server application and data are not compromised.

VCEM can be restored to an operational state after complete loss of the VCEM Application or
Database. While it is possible to restore VCEM to its state before the loss, minor or major
configuration loss might occur, depending on the availability of a database backup. If no database
backup is available, then a large amount of information can be reconstructed from the contents of
the Virtual Connect modules.

It is important that you understand what information is stored in the database, and can be lost
without proper backup practices.

Table 12 (page 133)

describes what components are recovered

if there is not backup strategy in place.

Table 12 Components restored without a backup strategy

Management server stored components

Restored components

Unassigned server profiles

Local user accounts

VC Domain Groups

Network and SAN configurations

MAC and WWN exclusions

Assigned server profiles

The Domain Network and SAN Configuration and assigned Server Profiles can be recovered from
the Virtual Connect modules. The VC Domain Group definitions, MAC and WWN custom ranges,
and MAC and WWN address exclusions are stored only on the Management Server.

For more information on performing backups and restoring VCEM, see Backing up and restoring
HP Insight Software 6.3 Central Management Server (Windows)
available from the Insight Software
Information Library at

http://h18000.www1.hp.com/products/servers/management/unified/

infolibraryicm.html

.

No HP-predefined ranges for MAC and WWN addresses in VC Domain
Groups

After upgrading VCEM 1.40, VC Domain Groups that were using HP-predefined ranges for MAC
and WWN addresses will start using VCEM-defined ranges for new server profiles. VCEM 1.40
and later do not use HP-predefined ranges for MAC and WWN addresses.

Cannot change the MAC/WWN/Serial Number ranges in Virtual Connect
Manager when there are server profiles

After removing the VC Domain from a VC Domain Group, you might not be able to modify the
MAC, WWN, or Serial Number ranges in Virtual Connect Manager even after removing all server
profiles from the VC Domain. This situation occurs because the MAC, WWN, and Serial Number
ranges you entered when releasing the VC Domain from VCEM have addresses externally in use
by server profiles under VCEM control.

Backing up and restoring VCEM

133

This manual is related to the following products: