Using flexfabric modules – HP Insight Management-Software User Manual
Page 73
There are two ways a VC Domain with a configuration mismatch is resynchronized:
•
Manually resynchronizing:
1.
Go to the VC Domains tab.
2.
Select the VC Domain with Configuration Mismatch status.
3.
Click VC Domain Maintenance. A dialog box showing the VC Domain to be resynchronized
appears.
4.
Click OK to confirm. The Virtual Connect Enterprise Manager is executing
the request
message appears with a job ID code.
5.
Click OK to go to the Jobs page and monitor job progress.
•
Automatically resynchronizing:
If VCEM detects a configuration mismatch, it starts auto resynchronization when you perform
a server profile operation.
displays restoring the VC Domain configuration in the
job details.
Figure 45 Job details
Replacing the HP 1/10 Gb VC-Enet or the HP 1/10 Gb-Enet modules
To upgrade the HP 1/10 Gb VC-Enet module or the HP 1/10 Gb-Enet module to use the HP VC
Flex-10/10D module see sections
“Replacing VC Ethernet modules with FlexFabric modules in an
existing VCEM managed VC Domain” (page 74)
or
“Replacing VC Ethernet in interconnect bays
three to eight with FlexFabric in an existing VCEM managed VC Domain” (page 75)
.
Using FlexFabric modules
This section describes scenarios to add or replace existing Ethernet and FC modules with FlexFabric
modules.
NOTE:
For general information about replacing VC modules with or without removing the VC
Domain, see
“Replacing VC modules” (page 174)
Replacing the HP 1/10 Gb VC-Enet or the HP 1/10 Gb-Enet modules
73