from FCoE to Ethernet. Also update the server profiles by removing the FCoE connections that
are linked to Flex-10/10D modules.

LACP timers

Do not configure LACP timers in VC Domains, Uplink Sets, or networks with a Long (30 sec)
value. For VC Domain configurations (see

Figure 15

) there are two possible values:

Short (1 second)

Long (30 second)

For network (see

Figure 16

) and Uplink Set (see

Figure 17

) there are three possible values:

Domain-Default which is either Short (1 second) or Long (30 second)

Short (1 second)

Long (30 second)

When the LACP timer configuration is set to long in VC Domains, all Uplink Sets and networks
with a default are automatically using Long (30 sec).