Cannot resynchronize VC Domain that has a configuration mismatch state
due to an enabled VC feature
If VCEM failed to resynchronize a VC Domain that is in a configuration mismatch state because
there are one or more VC features enabled (see
) you will need to perform the following
steps to correct the VC Domain:
Figure 92 Configuration mismatch details
1.
Telnet into VCM using an SSH connection such as SSH
[email protected]
, where xxx is the VC Domain IP address to access
the VCM CLI.
2.
Enter show external-manager at the VCM command prompt to determine the user name
of the external manager account. For this example, assume that the user name that is returned
is xyz.
3.
Enter set external-manager Username=xyz Enabled=false to temporarily disable
the account.
4.
Identify the features that are enabled and disable them. See
Domain to a VC Domain Group” (page 31)
for more information on enabled features.
5.
Enter set external-manager Username=xyz Enabled=true from the VCM command
prompt to enable the account.
6.
Perform the VC Domain resynchronization operation again. For more information, see
“Resynchronizing a VC Domain with Configuration Mismatch” (page 72)
.
Updating VC firmware versions in a VC Domain to be compatible with
VC 3.7x or later
Since the release of VCEM 7.1.1 or later, VC firmware versions 3.7x and later are not compatible
with VC firmware versions prior to 3.3x.