HP XP Command View Advanced Edition Software User Manual
Page 483
8.
Check the backup catalog information that was imported into the backup server.
PROMPT> drmexgcat
STRAGEGROUP: STR1
BACKUP-ID:0000000001 BACKUP-MODE: VSS STRAGEGROUP: STR1 ORIGINAL-ID:0000000001
START-TIME:2007/11/01 10:00:00 END-TIME: 2007/11/01 10:05:00 HOSTNAME:EXG_SRV1
T OBJECT INFORMATIONSTORE FILE FS DG DEVICE
COPY-GROUP
M MAILBOXSTORE MAILBOX1(STR1) D:\STR1\priv1.edb D: - Harddisk1
EXG001,B001
- - - - - - -
EXG001,B001
P PUBLICSTORE PUBLIC1(STR1) D:\STR1\pub1.edb D: - Harddisk1
EXG001,B001
- - - - - - -
EXG001,B001
T TRANSACT - E:\STR1\E00*.log E: - Harddisk2
EXG002,B001
- - - - - - -
EXG002,B001
C CHECKPOINT - E:\STR1\E00.chk E: - Harddisk2
EXG002,B001
- - - - - - -
EXG002,B001
PROMPT>
9.
Mount the secondary volume where the backup data is stored.
Specify the backup ID that was assigned when the backup was imported (
0000000001
) to mount
the secondary volume.
PROMPT> drmmount 0000000001 -mount_pt W:
KAVX0001-I The drmmount command will now start.
KAVX0400-I Mounting will now start.
Mount point = W:
KAVX0401-I Mounting has finished.
Mount point = W:
KAVX0400-I Mounting will now start.
Mount point = X:
KAVX0401-I Mounting has finished.
Mount point = X:
KAVX0002-I The drmmount command will now end.
PROMPT>
Application Agent CLI User Guide
483