Specifying settings for using vss, Specifying set- tings for using vss – HP XP Command View Advanced Edition Software User Manual
Page 148
Default
Description
Parameter
You can use the SQL Server log file to check the
amount of time from the beginning to the end
of automatic recovery of the system databases
(
master
,
model
,
msdb
, and
tempdb
).
Specifying settings for using VSS
If you want to use VSS to perform an online backup of a file system or an Exchange database, the
following settings are required:
•
The Application Agent and RAID Manager environments must be set up so that Application Agent
can perform VSS backups. Moreover, it is necessary to create a pair before backup. When creating
a pair, specify the
-m noread
option in the
paircreate
command.
•
P9000 RMXP Shadow Copy Provider must be installed in advance on the file server, or both the
database server and the backup server. Note that if P9000 RMXP Shadow Copy Provider has not
been installed on the servers when Application Agent is installed, P9000 RMXP Shadow Copy
Provider will be installed together with Application Agent. For details about how to install P9000
RMXP Shadow Copy Provider separately, see RAID Manager documentation.
Before you install P9000 RMXP Shadow Copy Provider, use the Services pane in the Windows
to make sure that the Windows services are set to the default settings shown in the following table:
Table 41 Default settings for Windows services related to P9000 RMXP Shadow Copy Provider
Startup type
Displayed name
Service name
Automatic
Remote Procedure Call (RPC)
RpcSs
Automatic
Event Log
EventLog
Automatic
DCOM Server Process Launcher
DcomLaunch
Automatic
Security Accounts Manager
SamSs
Automatic
Windows Management Instrumentation
winmgmt
Manual
COM+ Event System
EventSystem
Manual
Windows Installer
MSIServer
Manual
Volume Shadow Copy
VSS
Manual
COM+ System Application
COMSysApp
Manual
Distributed Transaction Coordinator
MSDTC
If you attempt to install P9000 RMXP Shadow Copy Provider when these Windows services are
not set to their default settings, the P9000 RMXP Shadow Copy Provider service will not be re-
gistered as a Windows service. In such a case, when the backup command is executed when
VSS is specified in the
-mode
option, an error message will be displayed and processing will
terminate with an error.
•
The execution of the
raidvchkset
command, described in the RAID Manager manual, is not
necessary.
Preparation for using Application Agent
148