HP XP Command View Advanced Edition Software User Manual
Page 116
NOTE:
To utilize, for example, the volume replication function within the storage system when the RAID
Manager instance for managing the primary volumes and the RAID Manager instance for managing
the secondary volumes are on the same server, specify the instance numbers as indicated below:
- Specify both
HORCMINST
and
HORCMINST_AUX
.
For instance numbers to specify for
HORCMINST
and
HORCMINST_AUX
, see
- The values for
HORCMINST
and
HORCMINST_AUX
are reversed when specifying settings for either
file servers and database servers, or for backup servers.
To utilize, for example, the volume replication function between storage systems when the RAID
Manager instance for managing the primary volumes and the RAID Manager instance for managing
the secondary volumes are on separate servers, specify the instance numbers as indicated below:
- Specify only
HORCMINST
(not
HORCMINST_AUX
).
For instance numbers to specify for
HORCMINST
, see
- The RAID Manager instances specified in
HORCMINST
must be started on each server.
If a RAID Manager instance which is not located on the server is specified in
HORCMINST_AUX
, an
error message indicating failure to start the RAID Manager instance is output to the application log.
If the instance is not associated with the subject of processing, processing of the Application Agent
command will continue despite this error message. Also, the result of the command will not be affected.
It is recommended that you start the RAID Manager instances specified in
HORCMINST
and
HORCMINST_AUX
before executing a Application Agent command.
When specifying multiple instance numbers in
HORCMINST
and
HORCMINST_AUX
, write each
instance number on a separate line, as shown below:
HORCMINST=0
HORCMINST_AUX=1
HORCMINST=2
HORCMINST_AUX=3
In a cluster configuration, all servers making up the cluster must share the
HORCMINST
and
HORCMINST_AUX
instance numbers in
DEFAULT.dat
.
•
You can create two identical
DEFAULT.dat
files, and then place one
DEFAULT.dat
file on one
server and the other
DEFAULT.dat
file on the other server.
Table 24 Parameters in the RAID Manager-linkage definition file (DEFAULT.dat) (to specify an
instance number)
Default
Description
Parameter
Backup server
File server or database
server
None
Specify the instance number
of the instance that man-
ages the secondary volume.
Specify the instance number
of the instance that man-
ages the primary volume.
HORCMINST
#1, #2
None
Specify the instance number
of the instance that man-
ages the primary volume.
Specify the instance number
of the instance that man-
ages the secondary volume.
HORCMINST_AUX
#3
#1: The
HORCMINST
parameter is a required parameter.
Preparation for using Application Agent
116