Error reporting

If errors occur in the input file, HP SUM exits with a return value of –2 (bad parameter). The details
of the location and nature of the error are recorded in
hpsum_execution_log__

.

Input file parameters

Possible values

Description

Parameter

YES

, NO

This parameter causes the installation
to run silently without GUI or console

SILENT

output. All data is written to the log
file. Any generated prompts use the
default option and continue the
installation without user input.

If a component requires input before
installation (such as configuration
information), the component
installation fails (unless the
IGNOREERRORS

=

"FailedDependencies" parameter is
supplied), and an error message is
written to the log file.

/targettype vc

This parameter specifies the node type
and can shorten the inventory process.

TARGETTYPE

The following are valid node types:

Server

Windows

Linux

HPUX

EVA

or Command View for

EVA

FC Switch

or Fibre

Channel Switch

OA

or Onboard

Administrator

SUPERDOME 2

or

SUPERDOME2

or Superdome

2 Onboard Administrator

iLO

VC

or Virtual Connect

HP SAS

or HP SAS B/L

Interconnect Switch

VMware

or VMware Host

iPDU

or Intelligent

Power Distribution Unit

(iPDU)

If you use the command with a
group, the HP SUM assumes all
nodes in the group are the same
node type.

YES

, NO

Forces updates to both firmware and
software components.

FORCEALL

YES

, NO

Forces updates to firmware
components.

FORCEROM

50