Error reporting, Input file parameters, Error reporting input file parameters – HP Smart Update Manager Version 6.0.0 User Manual
Page 50
Error reporting
If errors occur in the input file, HP SUM exits with a return value of –2 (bad parameter). The details
of the location and nature of the error are recorded in
hpsum_execution_log_
.
Input file parameters
Possible values
Description
Parameter
YES
, NO
This parameter causes the installation
to run silently without GUI or console
SILENT
output. All data is written to the log
file. Any generated prompts use the
default option and continue the
installation without user input.
If a component requires input before
installation (such as configuration
information), the component
installation fails (unless the
IGNOREERRORS
=
"FailedDependencies" parameter is
supplied), and an error message is
written to the log file.
/targettype vc
This parameter specifies the node type
and can shorten the inventory process.
TARGETTYPE
The following are valid node types:
•
Server
•
Windows
•
Linux
•
HPUX
•
EVA
or Command View for
EVA
•
FC Switch
or Fibre
Channel Switch
•
OA
or Onboard
Administrator
•
SUPERDOME 2
or
SUPERDOME2
or Superdome
2 Onboard Administrator
•
iLO
•
VC
or Virtual Connect
•
HP SAS
or HP SAS B/L
Interconnect Switch
•
VMware
or VMware Host
•
iPDU
or Intelligent
Power Distribution Unit
(iPDU)
If you use the command with a
group, the HP SUM assumes all
nodes in the group are the same
node type.
YES
, NO
Forces updates to both firmware and
software components.
FORCEALL
YES
, NO
Forces updates to firmware
components.
FORCEROM
50
Using legacy scripts to deploy updates