Description

Superdome 2 server commands

Example: /device_list
npar1,npar2,blade1/1,blade1/2

Use this argument when the /update_type is ALL or
PARTITIONS

. This argument specifies specific partitions

/reboot_list

to reboot after the partition firmware has been updated.
Valid npar values are npar(number). Do not put any
spaces between parameters.

Example: /reboot_list npar1,npar2

Command-line examples

The following command-line parameter examples can be executed within these environments:

Firmware:

System ROM

Smart Array controller

Hard drives

iLO

Software—later version of:

HP Insight Diagnostics Online Edition for Windows Server 2003 (cp008097.exe)

HP System Management Homepage (HP SMH) for Windows (cp008257.exe)

HP SUM

Defined groups: Management Servers—three servers (Management Server1, Management
Server2, Management Server3)

Example 1:

This command-line input deploys the latest PSP and firmware components:

hpsum /use_latest /allow_non_bundle_components /silent

Results: All software components and firmware components from the update bundle, which HP
SUM determined must be installed, were installed.

Example 2:

Either of the following command-line inputs can deploy the previous version of the PSP only and
force all the components to be installed:

hpsum /f:bundle /softwareonly BP000315.xml

hpsum /b BP000315.xml /f:bundle /softwareonly

Results: All software components and firmware components from the update bundle, which HP
SUM determined must be installed, were installed. No firmware was installed.

Example 3:

This command-line input deploys firmware:

hpsum /romonly

Results: All firmware components that must be installed, were installed. No software was installed.

Example 4:

Command-line interface