HP Smart Update Manager Version 6.0.0 User Manual

Page 43

background image

Description

Nodes

If the node name includes spaces, make sure you enclose
the name in quotation marks, “ “.

NOTE:

/targettype

is an optional command line

argument. Use /targettype and /target together.

Enables the credential of the local host to be used as the
credential to access the nodes instead of providing the user

/current_credential

name and password explicitly for each node. The
assumption is that the current credential is valid for the
nodes being accessed. (Applies to Windows only)

This argument provides the user name credential for OA
associated with VC specified with the target

/oa_username

command-line parameter. Only one set of OA credentials
can be specified with command-line parameters. You can
add multiple VC nodes to command-line parameters with
the target parameter only if the credentials of OAs
associated with specified VCs are the same. You do not
need to provide an OA network address associated with
VC. HP SUM queries it from a specified VC node.

To update multiple VCs with different user names and
passwords, or VCs with OAs that have different credentials,
use the corresponding input files OAUID and OAPWD.

Provides the password credential for OA associated with
VC specified with the "node" command-line parameter.

/oa_password

Only one set of OA credentials can be specified with
command-line parameters. You can add multiple VC nodes
to command-line parameters with the "node" parameter
only if the credentials of OAs associated with specified
VCs are the same. You do not need to provide an OA
network address associated with VC. HP SUM queries it
from a specified VC node.

To update multiple VCs with different user names and
passwords, or VCs with OAs that have different credentials,
use the corresponding input files OAUID and OAPWD .

Description

Log files

Redirects the output from HP SUM or the HP BladeSystem
c-Class OA flash utility to a different directory than the
default location.

/logdir

“path"

For Windows components, the default location is
%SYSTEMDRIVE%\CPQSYSTEM\hp\

log

and the redirected location is

\hp\log\

.

For Linux components, the default location is /var/hp/
log/

and the redirected location is

/hp/log/

.

Sets the verbosity level for the HP SUM execution log file,
hpsum_execution_log__

. It

/v[erbose]

or /veryv[erbose]

increases the level of detail that is retained in the log file.
The default value is normal verbosity.

Description

Generating reports

Generates a report listing of the node summary and
describes how the components in the repository affect the

/report

node; for example, whether each component applies to
the node. The report is generated in HTML and XML with

Command-line interface