Chapter 3. Operation

3-28

TSU User Manual

61200060L1-1

4)CLR 511 ERRORS

- Accomplishes two functions. First, it

clears out the 511 error total when

ENTER

is pressed. Second,

it displays a total of the 511 errors. If 511 errors are being
received, the display is updated accordingly.

This menu function is very useful for testing end-to-end
integrity of the network. First loopup the far end TSU. Then
send a 511 pattern from the local TSU. The CLR 511 ERRORS
screen can then be used to determine if the link is functioning
properly by verifying that no errors are being counted.

2)Run Selftest, Submenu of 4)Test

This menu selection is used to execute an internal self test.
This is the same self test that is performed automatically at
power up. The results of the self tests are displayed in the
LCD. Upon invoking the command the LCD displays

INITIALIZING

and test failures are displayed in the LCD

window. The self test procedure consists of the following
tests.

Ram tests; EPROM checksum

On board data path. Sending a known test pattern
through an on-board loop

Front Panel LED verification

Phase Lock Loop verify

If a failure is detected, note the failure number prior to
contacting ADTRAN technical support.

C L R 5 1 1 E R R O R S

5 1 1 E R R O R S = 5 6

Executing a self test will disrupt normal data flow and prevent re-