Chapter 1. Introduction

1-6

TSU User Manual

61200060L1-1

Network Interface

The Network Interface (NI) port complies with the applicable
ANSI and AT&T standards.

NI

AMI or B8ZS coding

Automatic or manual line build out

D4 or ESF framing

Network performance monitoring and reporting

Test loopbacks by local and remote

Extensive self test

Nx56/64 Serial Interface

Data rates: N*56k or N*64k, where N=1 to 24 (DS0s)

Inverted data (Inverted HDLC)

A V.35 interface

Standard V.35 connectors

Test loopbacks with 511 pattern generation and check

Extensive self test

Control Por t Input

EIA-232 input from a PC or a modem for control of the
TSU

Chain input from another TSU

Up to 9600 baud operation

Acts as input for PC proxy agent control or as input for a
chained connection

Chain Por t Output

EIA-232 output to chain control to other TSUs

Up to 9600 baud operation

Automatic setup; no user input required