beautypg.com

Curr err/alm submenu of 1)status -12 – ADTRAN T1-FT1 User Manual

Page 48

background image

Chapter 3. Operation

3-12

TSU User Manual

61200060L1-1

CURR ERR/ALM Submenu of 1)Status

The Current Error/Alarm menu is used for viewing currently
Active/Inactive errors and alarms.

1.

With the cursor on main menu item 1)S

TATUS

, press

ENTER

.

The first of three Status submenu items with the

cursor on 1)NI PERF RPTS displays.

2.

Press the down scroll key.

3.

Press

ENTER

.

The results display the first current E

RRORS

/A

LARMS

screen.

The up and down scroll keys are used to access the complete
display of the errors/alarms that are currently active. The
alarms and errors which can be seen are shown below.

L O S S O F S I G N A L

A C T I V E

Alarm Investigated

State (Active/Inactive)

Loss of Signal

No pulses received at NI.

AIS Alarm

Unframed All-Ones received at NI.

Out of Frame

No framing pattern sync at NI

Yellow Alarm

Receiving yellow alarm pattern from
NI.

Red Alarm

LOS/OOF causing red alarm at NI.

Code Violations

CRC errors in ESF, or BPVs in SF were
received at NI.

Bipolar Violations

BPVs in SF or ESF.

Frame Bit Errors

Frame Bits received incorrectly at NI.

PLL Alarm

Unable to sync up to selected clock
source.