Performance specifications – PNI TCM 2.6 User Manual
Page 45
PNI Sensor Corporation
DOC#1009269 r11
TCM2.5 & TCM2.6 User Manual
Page 45 of 49
Performance Specifications
Parameter
Typical
Units
Heading Specifications
Accuracy over tilt range
0.8°
Deg RMS
Resolution
0.1°
Repeatability [1]
0.1°
Max Dip Angle
85°
Deg
Magnetometer Specifications
Calibrated Field Measurement
Range
± 80
µT
Magnetic Resolution
± 0.05
Magnetic Repeatability
± .1
Tilt Specifications
Pitch Accuracy
0.2°
Deg RMS
Roll Accuracy
0.2°
Tilt Range
± 50°
Deg
Tilt Resolution
0.1°
Tilt Repeatability [1]
0.1°
Deg RMS
Calibration
Hard Iron Calibration
Yes
Soft Iron Calibration
No
Mechanical Specifications
TCM2.5
TCM2.6
Dimensions (L x W x H)
6.4 x 5.1 x 1.4
3.4 x 4.3 x 1.3
cm
Weight
14
7
grams
Mounting Options
Screw Mounts/Standoffs horizontal
Connector for RS-232
10-pin
9-pin
I/O Specifications
Time to Good Initial Data from
Power-On
210
msec
Time to Good Initial Data from
Sleep Mode
80
msec
Maximum Sample Rate
8
samples/sec
RS-232 Communication Rate
300 to 115200
baud
Output Formats
TCM2 ASCII Protocol
Power Specifications
TCM2.5
TCM2.6
Supply Voltage
5 V (regulated)
6 to 18 (unregulated)
3.8 to 5.0 V
(unregulated)
VDC
Current Draw at
maximum sample rate
20 typical
20 typical
mA
Sleep Mode
0.6 typical
0.6 typical
Environmental Specifications
Operating Temperature
– 20 to 70
°C
Storage Temperature
– 40 to 85
[1] Repeatability is based on statistical data at ±3 sigma limt about the mean
Table 25: TCM2.5/2.6 Specifications